Photovoltaic inverter (PV inverter or solar inverter) can convert the variable DC voltage generated by photovoltaic (PV) solar panels into an inverter with mains frequency alternating current (AC), which can be fed back to commercial transmission system or used for off grid power grid. Photovoltaic inv🐠erter is one of the important system balance (BOS) in photovoltaic array system, which can be used with general AC power supply equipment.
In 2014, the conversion efficiency of ℱadvanced photovoltaic inverters can reach 98%, in which the string inverter will use residential or medium-sized photovoltaic systems, while the central inverter will use large-scale commercial systems and even grid level markets. The market share of central inverter and series inverter is 50% and 48% respectively, and the market share of micro inverter is less than 2%.
Product Name | VCES[V] | IC @100℃[A] | VCE(sat), typ @25℃[V] | Eon, typ @25℃[mJ] | Eoff, typ @25℃[mJ] | tsc, typ @125℃[μs] | package |
---|---|---|---|---|---|---|---|
TGL75N120FDR | 1200 | 75 | 1.79 | 8.48 | 3.18 | 5us(min) | TO-264 |
TGAN40N120FDR | 1200 | 40 | 2 | 3.66 | 0.79 | 10 | TO-3PN |
TGAN80N65F2DS | 650 | 80 | 1.85 | 3.05 | 1.11 | - | TO-3PN |
TGAN60N65F2DR | 650 | 60 | 1.6 | 2.07 | 0.97 | 5us(min) | TO-3PN |
TGH40N65F2DR | 650 | 40 | 1.6 | 1.06 | 0.55 | 5us(min) | TO-247 |